- 26 -
Control unit
EN
ENGLISH
6.2
J3A/J3B
POWER TERMINAL BLOCK
MOTA
COM
MOTB
M
CAP
CAP
EV1
AC2
EV2
AC2
SEM GRN
AC2
SEM RED
AC2
LAMP
AC2
6.3
J4
OUTPUTS/ACCESSORIES TERMINAL BLOCK
OUT5
2ndRX
24 Vac2
OUT LED
24 Vac2
24 Vac2
OUT BUZZER
BRK-
BRK+
OUT4
AUX
COM
OUT LED
COM
OUT BUZZER
MOT A - COM - MOT B
Motor connection, MOT A for open direction and MOT B for close direction
CAP
Capacitor if not present on motor(s) side
EV1
Electrovalve (230Vac RAC), for hydraulic bollards only
EV2
Electrovalve (230Vac RAC), for ECD bollards equipped only
TRAFFIC LIGHT - GREEN LAMP
Tra c light outputs green lamp (230Vac)
TRAFFIC LIGHT - RED LAMP
Tra c light outputs red lamp (230Vac)
FLASHING LIGHT
Flashing light, (230Vac)
EF ELECTRIC BRAKE OUTPUT (Electomechanical bollards only)
Connection for two white power supply cables for the motor’s parking electric brake.
Activation is possible only when the bollard is completely lifted (24Vcc starting / 12Vcc to stand on).
Power supply for accessories
24Vac, 1A max
Cover lights 24Vac
Self-powered output. 24Vac, 800mA max
Cover lights 12Vac (XPASS B 1200C only)
Self-powered output. 12Vac, 800mA max
Cover buzzer 24Vac
Self-powered output. 24Vac, 100mA max
Cover buzzer 12Vac (XPASS B 1200C only)
Self-powered output. 12Vac, 100mA max
OUT4/AUX
Programmable free contact relay output, max. 500mA 24 Vac/dc (parameter D8 - level 2)
OUT5/2ndRX
Programmable free contact relay output/ N.O. output of the 2nd radio receiver channel; 500mA max, 24Vac/dc
(parameter D8 - level 2)