- 33 -
Control unit
EN
ENGLISH
Description of level 3 parameters
· 3G: Input polarity
For N.O. or N.C. input polarity con guration.
·
33: Output 4 polarity, Output 5 polarity
Output polarity: The outputs can be con gured as N.O. or N.C.. NOTE: in the event of a power failure the N.C. contact opens anyway.
· 3$: Output polarity
The outputs can be con gured as N.O. or N.C.. NOTE: in the event of a power failure the N.C. contact opens anyway.
· &3: Enable command during the pause time
Depending also upon other settings, the system accepts or not the commands from inputs.
·
)3: Special PDM functions
)3= PDM is used as opening enable. As long as it is not active, no opening command is accepted. Also no close command is ac-
cepted so the bollard remains open.
)3= The PDM functions as described in point 1, but in case of automatic logic, the pause time is reloaded.
)3= The PDM function enables the TERMON system. Based on the setting of the 3' parameter, the closing or opening of the
contact activates or deactivates the TERMON system. This allow the TERMON function to be controlled by a calendar and/or
a thermostat.
· 33: Pressure switch polarity
N.O.: Pressure switch type used until 2012.
N.C.: Pressure switch type used from 2013 on.
The following table gives the 4th level functions and the adjustable parameters.
= DEFAULT value set in factory.
= parameter value set during installation: should be lled if
DEFAULT value is modi ed.
8.5
4TH
LEVEL PROGRAMMING
)3
Programmable PDM input for spe-
cial functions
: None
: Opening Enable when active
: Opening Enable and pause time reset (with 3U=), when active
: TERMON Enabled when active
: Opening Enable and pause time reset (with 35=), when active
5
Radio channel 1 command selec-
tion
: Receiver channel 1 not used
: Receiver channel 1 mapped to START
: Receiver channel 1 mapped to OPEN (with SU= special function)
+W
Select mains frequency : Value of main frequency in Hertz (Hz)
67
Exiting the menu/saving Pressing the “F” key exits the programming menu and changes are saved
Par Function Settable data
&R0
Communication protocol
: disabled
: U-LINK
: Modbus/RTU
X0R
U-LINK mode
: Slave
: Master
X,G
U-LINK adress
0,G
Modbus/RTU ID
: For Slave
: For Master
063
MODBUS RTU speed
.: 19 200 baud
.
. 38 400 baud
727
Cycles counter Read only parameter, in thousands (x1000)
(UU
Historical errors
: do not clear (keeps) the list
: clear the list