6.4
J5A/J5B
INPUTS TERMINAL BLOCK
FCC
COM
FCA
COM
COM
BRK+
FCC
COM
BRK +
FCA
STOP
N.C. safety input. When it is activated, the automation is immediately stopped. During the pause time, a stop control eliminates
the automatic closing, leaving the bollard open waiting for a command.
FTC
N.C. photocell input. It allows the automation to be closed only if the safety devices have not triggered. Operating mode
programmable with parameter )W-level 1.
CLOSE
N.O. closing input. It allows the automation to be closed only if the safety devices have not triggered. Operating mode pro-
grammable with parameter &/-level 1.
OPEN
N.O. opening input.
By keeping this input controlled, the automation performs the opening manoeuvre and will close automatically only when the
input is freed. Connect clocks, daily timers or weekly timers here if wanted.
START
N.O. input that operates the bollard’s opening and closing. The command is ignored while opening
PDM
Programmable Input 3G-3°liv..
May be duplicated on AUX output.
PRES 1
Closure travel limit pressure switch input (see parameter SS- level 3). Limit switch N.C. input in closing.
When activated the closing travel nishes (For hydraulic bollards only).
PRES 2
ECD pressure switch input (see parameter 3(- level 3 and parameter()- level 2).
(For ECD equipped bollards only).
UPS
UPS status input. To be connected to smart UPS with status output, active-high during mains failure. The control unit has also
an internal detector that works with simpler square-wave and quasi-sinusosidal UPS. With these simpler UPS there is no need
to use this input.
AUXILIARY INPUT AUX
For bollards with ECD device. Is active when emergency ECD command is active (see parameter SI- level 3)
ANALOG INPUT
Multi-purpose analog input 0..5V
ANTENNA
Antenna connection for the radio receiver (option).
FCC
2 wire N.O. closing limit switch imput (set parameter /7 - level 3and parameter I& - level 2).
When activated the opening travel ends (XPASS B 800C).
3 wire N.O. closing limit switch imput (set parameter /7 - level 3and parameter I& - level 2).
When activated the opening travel ends (XPASS B 1200C).
FCA
2 wire N.O. opening limit switch imput (set parameter /7 - level 3). When activated the opening travel
ends.
3 wire N.O. opening limit switch imput (set parameter /7 - level 3). When activated the opening travel
ends (XPASS B 1200C).