- 38 -
Control unit
EN
ENGLISH
RECOMMENDED DIMENSIONS
This solution is recommended when you want to allow entry to a reserved area, without using any commands, allowing transit of vehicles in
just one direction.
The vehicle approaches the
reserved area. When over the
loop S1, the bollard goes down.
When the vehicle is no longer
over loop S2, the bollard will
rise again.
Loops S1 and S2 also have a safety function in that they will not let the bollard to move all the time if the vehicle is over S1 or S2.
13.2
INSTALLATION B
AUTOMATIC ENTRY OR EXIT
ONE DIRECTION
ONE DIRECTION
ONE DIRECTION
PARAMETER DATA DESCRIPTION
35=
&/
The close command acts as a close-when-released and safety function.
5
Radio channel 1: Disabled
)S
Opening consent
/2
Semiautomatic logic
&3
Command during pause is OFF
- Connect the N.O. contact of the coil receiver S1 to the OPEN input.
- Connect the N.O. contact of the S2 loop receiver to the CLOSE input.
- The dimensional values given are only approximate.
We suggest installing the “RME 2” metal mass detector.
*