- 30 -
Control unit
EN
ENGLISH
8.2
1st LEVEL
PROGRAMMING
The following table gives the 1st level functions and the adjustable parameters.
= DEFAULT value set in factory.
= parameter value set during installation: should be  lled if
DEFAULT value is modi ed.
Description of level 1 parameters
·
/R: Functioning logic
- Hold-to-run: Close function active for as long as inputs are active. Open function activated by activating and releasing input. The
start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control closing
you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic reclosing is
activated after the pause time set (parameter W3).
Par Function Settable data
/R
Selects the functioning logic.
(see notes after the table)
: Hold-to-run

: Semi automatic
: Automatic
&/
Close input con guration (see
notes after the table)
: Standard close input

: Close-when-released input
: The close command acts as a close-when-released and safety function.
)W
Photocells
: During, it reopens and waits for the photo cell free commands closing.

: When closing it reopens; closes after 1’ when the photocell is free
: When closing it reopens; closes after 5’ when the photocell is free
2E
Obstacle detection
(for hydraulic bollards only)
: Disabled

: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, then closes after 5 seconds
S2
Opening-warning time


S&
Closing-warning time


/'
Bollard lights
: Cover lights  ashing during movement,  xed on when the bollard is
opened and closed

: Cover lights  ashing during movement and with bollard open,  xed on
when the bollard is closed
: Cover lights always  ashing
: Cover lights  ashing during movement and with bollard closed,  xed
on when the bollard is open
W3
Pause time (in seconds) -

%X
Buzzer
: Buzzer o

: Buzzer on during movement
3U
Preset controlling entrance
con guration
: none

: Con guration of installation type A parameter (see chapter 13.1)
: Con guration of installation type B parameter (see chapter 13.2)
: Con guration of installation type C parameter (see chapter 13.3)
: Con guration of installation type D parameter (see chapter 13.4)
G)
Resetting default parameters.
(see notes after the table)
: No resetting

: Resetting the default parameters
: Same as , except for “COM” parameters that are not reset
67
Exiting the menu/saving Pressing the “F” key exits the programming menu and changes are saved