Item# Fig. PN Description
------- ---- ----- ---------------------------------
66 3 A1483 Connector Gasket
67 3,5 BUNA116 O-Ring
86 2 SC1014 #8x1" Sheet Metal Screws
87 2 A1403 Inlet/Outlet Tube
88 2 SC1013 #8x5/8" Sheet Metal Screws
146 7 SC3030 #6-32 x 3/8" Philips pan head screw
147 7 1705-L5 10 micron inlet top
148 7 1709-L9 Spacer
149 7 1709-L8 Screen
150 7 1711-L11 10 micron inlet sub top
151 7 1712-L12 10 micron inlet body
152 7 Viton-036 O-ring
153 7 DI1013 10 micron inlet tube
154 7 SC3031 1/4 x 3/8 NPT adapter (Old Style)
155 7 SC3032 1/4 NPT nipple (Old Style)
156 7 JC3033 Jar top
157 7 SC3034 1/4 NPT plug (Old Style)
158 7 JR3035 Glass jar
159 7 Buna-026 O-ring
-- - ICA002 Internal Battery Cable Assembly
-- - ICA003 Flow Sensor Cable Assembly
164 7 SC3036 1/4" NPT Hex Nipple
10.2 Rebuilding the Pump after 5000 Hours
To determine "Pump Cumulative Time" you must use the PQ software to obtain a
download from the PQ100 (See Section 8.9). Pump Cumulative time is the number of
actual service hours of the dual diaphragm pump and is shown when either printing or
screen viewing a download. When this time exceeds 5000 hours the pump should be
rebuilt. The rebuild is a relatively easy task and requires the replacement of the
diaphragms, valves, and bearing. A kit of parts is available from the factory and includes
instructions. Service can also be performed by the factory.
Kit # Description
X014 Pump Rebuild Kit (Includes valves, diaphragms and Ao@ rings)
X015 Advanced Pump Rebuild Kit (Includes X014 with bearing)
X016 Total Pump Rebuild Kit (Includes X014 with bearing and motor)
X017 Pump Diaphragms Only