Issue 07/2017 Art. No. 7001-0333
Operating Manual
CB (E6.1)
CO
2
- Incubators
CO
2
Incubators with O
2
control
with sterilizable NDIR sensor system for CO
2
and microprocessor controller T4.12
Model Voltage Equipment Art. No.
CB 60
230 V 9040-0088, 9140-0088
CB 60-UL
100-120V
9040-0089, 9140-0089
CB 60
230 V
O
2
control
9040-0090, 9140-0090
CB 60-UL
100-120V
O
2
control
9040-0091, 9140-0091
CB 60
230 V
Divided inner door
9040-0104, 9140-0104
CB 60-UL
100-120V
Divided inner door
9040-0105, 9140-0105
CB 60
230 V
O
2
control
Divided inner door
9040-0106, 9140-0106
CB 60-UL
100-120V
O
2
control
Divided inner door
9040-0107, 9140-0107
CB 160 (E6)
230 V
9040-0092, 9140-0092
CB 160-UL
100-120V
9040-0093, 9140-0093
CB 160 (E6)
230 V
O
2
control
9040-0094, 9140-0094
CB 160-UL
100-120V
O
2
control
9040-0095, 9140-0095
CB 160
230 V
Divided inner door
9040-0100, 9140-0100
CB 160-UL
100-120V
Divided inner door
9040-0101, 9140-0101
CB 160
230 V
O
2
control
Divided inner door
9040-0102, 9140-0102
CB 160-UL
100-120V
O
2
control
Divided inner door
9040-0103, 9140-0103
CB 220
230 V
9040-0096, 9140-0096
CB 220-UL
100-120V
9040-0097, 9140-0097
CB 220
230 V
O
2
control
9040-0098, 9140-0098
CB 220-UL
100-120V
O
2
control
9040-0099, 9140-0099
CB 220
230 V
Divided inner door
9040-0108, 9140-0108
CB 220-UL
100-120V
Divided inner door
9040-0109, 9140-0109
CB 220
230 V
O
2
control
Divided inner door
9040-0110, 9140-0110
CB 220-UL
100-120V
O
2
control
Divided inner door
9040-0111, 9140-0111
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: service@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Questions and Answers

  • J
    jordanmonicaAug 17, 2025
    How to troubleshoot a Binder Laboratory Equipment chamber that is not working?
    • E
      Erika DunnAug 17, 2025
      If your BINDER Laboratory Equipment chamber isn't functioning, start by checking its connection to the power supply. Then, ensure the power supply matches the equipment's voltage requirements (100-120V or 200-240V). Also, inspect the chamber fuse and replace it if necessary. If the fuse blows again, it is recommended to contact BINDER service.
  • C
    Christopher RobertsAug 20, 2025
    What to do if the Binder Laboratory Equipment shows a "Low pressure CO" alarm?
    • K
      Kelly GreenAug 20, 2025
      To address a low CO outlet pressure in your BINDER Laboratory Equipment, first, confirm the alarm. Ensure the CO cylinder is correctly connected and opened. If the cylinder is empty, replace it, observing safety instructions and outlet pressure limits. Check the gas hose for obstructions; if dirty, turn off the gas supply, remove connections, and clean or replace the hose. If issues persist, it may be a controller or pressure sensor malfunction, and contacting BINDER Service might be necessary.
  • J
    jessicawhiteAug 23, 2025
    What to do if Binder CB 60-UL is constantly heating up?
    • J
      Jamie CordovaAug 23, 2025
      If your BINDER Laboratory Equipment chamber is heating permanently and exceeding the setpoint, confirm the alarm. Then, turn off the chamber, open the doors for about 5 minutes, and turn it back on. If the alarm reappears, or the temperature controller is not adjusted, calibrate and adjust the temperature controller. If the problem persists, contact BINDER service.
  • J
    Joshua BrooksAug 26, 2025
    What does it mean when my Binder CB 60-UL Laboratory Equipment shows a "Safety controller" alarm?
    • J
      Julie SantosAug 26, 2025
      If your BINDER Laboratory Equipment displays a "Safety controller" alarm due to excess temperature, confirm the alarm. Check the temperature setpoint and the safety controller class 3.1 setpoint, adjusting to a suitable value if needed. Also, reduce any external heat load affecting the chamber.
  • F
    floresjonathanAug 28, 2025
    Why is my Binder CB 60-UL Laboratory Equipment not heating up and showing a "Safety controller" alarm?
    • U
      ukruegerAug 28, 2025
      If your BINDER Laboratory Equipment isn't heating up and displays a "Safety controller" alarm, confirm the alarm and let the chamber cool down. Check the temperature setpoint and the safety controller setting, adjusting the limit value if necessary.
  • K
    Karen CrawfordAug 30, 2025
    What to do for a "Low pressure O" alarm on a Binder CB 60-UL Laboratory Equipment chamber?
    • B
      bianca77Aug 31, 2025
      To address a low O outlet pressure in your BINDER Laboratory Equipment, first, confirm the alarm. Ensure the O cylinder is correctly connected and opened. If the cylinder is empty, replace it, observing safety instructions and outlet pressure limits. Check the gas hose for obstructions; if dirty, turn off the gas supply, remove connections, and clean or replace the hose. If issues persist, it may be a controller or pressure sensor malfunction, and contacting BINDER Service might be necessary.
  • B
    blankenshipyvonneSep 2, 2025
    How do I fix a "Low pressure N" alarm on my Binder CB 60-UL Laboratory Equipment?
    • H
      Henry ThomasSep 3, 2025
      To resolve a low N outlet pressure in your BINDER Laboratory Equipment, first, confirm the alarm. Ensure the N cylinder is correctly connected and opened. If the cylinder is empty, replace it, observing safety instructions and outlet pressure limits. Check the gas hose for obstructions; if dirty, turn off the gas supply, remove connections, and clean or replace the hose. If issues persist, it may be a controller or pressure sensor malfunction, and contacting BINDER Service might be necessary.
  • G
    Gary BoydSep 5, 2025
    What should I do if my Binder CB 60-UL shows an "CO range" alarm?
    • A
      amanda15Sep 5, 2025
      If the CO concentration exceeds the set tolerance in your BINDER Laboratory Equipment, confirm the alarm. Turn off the chamber, open the doors for about 5 minutes, and observe safety guidelines for handling CO. Then, turn the chamber back on. If the alarm continues, it may be a defective CO sensor, and contacting BINDER Service might be necessary.
  • M
    Michelle OlsonSep 8, 2025
    What does it mean when my Binder CB 60-UL displays an "O range" alarm?
    • T
      Toni OrtizSep 8, 2025
      If the O concentration exceeds the set tolerance in your BINDER Laboratory Equipment, confirm the alarm. Turn off the chamber, open the doors for about 5 minutes, observe safety guidelines for handling oxygen, and prevent oxygen enrichment around the chamber. Then, turn the chamber back on. If the alarm continues, it may indicate a defective O sensor, and contacting BINDER Service might be necessary.
  • J
    Jeremy RandolphSep 12, 2025
    Why is my Binder CB 60-UL not reaching the set temperature?
    • K
      Karen McintoshSep 12, 2025
      If the setpoint temperature is not reached after a specified time in your BINDER Laboratory Equipment, ensure the chamber door is completely closed. If the issue persists, the door gasket may be defective and require replacement. Also, calibrate and adjust the temperature controller.

Binder CB 60-UL Specifications

General IconGeneral
Temperature range5 °C to 100 °C
Temperature uniformity±0.3 °C
Number of shelves standard/max2/5
Voltage120 V
Capacity57 liters
Heating Power1000 W
Weight52 kg
MaterialStainless steel
CertificationUL certified