EasyManuals Logo

BK Precision 9205 User Manual

BK Precision 9205
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #60 background imageLoading...
Page #60 background image
48
7 Specifications
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes
over an ambient temperature range of 23 °C ± 5 °C. Specifications are subject to change
without notice.
Environmental Conditions:
This power supply is designed for indoor use and operated with maximum relative humidity of
80%.
Model
9201
9202
9205
9206
Output Rating
Voltage
0-60 V
0-60 V
0-60 V
0-150 V
Current
0-10 A
0-15 A
0-25 A
0-10 A
Power
200 W
360 W
600 W
600 W
Line Regulation
Voltage
≤0.01%+5 mV
≤0.01%+8 mV
≤0.01%+15 mV
≤0.01%+15 mV
Current
≤0.05%+4 mA
≤0.05%+6 mA
≤0.1%+10 mA
≤0.05%+10 mA
Load Regulation
Voltage
≤0.01%+8 mV
≤0.01%+8 mV
≤0.01%+15 mV
≤0.01%+15 mV
Current
≤0.05%+6 mA
≤0.05%+6 mA
≤0.1%+10 mA
≤0.05%+10 mA
Ripple and Noise (20Hz-20MHz)
Voltage
≤8 mVpp
≤15 mVpp
≤20 mVpp
≤50 mVpp
Current
≤6 mArms
≤8 mArms
≤15 mArms
≤15 mArms
Programming Resolution
Voltage
1 mV
1 mV
1 mV
1 mV
Current
0.1 mA
0.1 mA
0.1 mA
0.1 mA
Readback Resolution
Voltage
1 mV
1 mV
1 mV
1 mV
Current
0.1 mA
0.1 mA (<10 A)
1 mA (>10 A)
0.1 mA (<10 A)
1 mA (>10 A)
0.1 mA
Programming Accuracy ± (%output+offset)
Voltage
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+20 mV
Current
≤0.1%+10 mA
≤0.1%+15 mA
≤0.1%+25 mA
≤0.1%+25 mA
Readback Accuracy ± (%output+offset)
Voltage
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+20 mV
Current
≤0.1%+10 mA
≤0.1%+15 mA
≤0.1%+25 mA
≤0.1%+25 mA
w ww . . co m
information@itm.com1.800.561.8187

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision 9205 and is the answer not in the manual?

BK Precision 9205 Specifications

General IconGeneral
BrandBK Precision
Model9205
CategoryPower Supply
LanguageEnglish

Related product manuals