33
4
MAV
16
Data is available in the power supply output buffer.
5
ESB
32
One or more bits are set in the standard event register
(bits must be “enabled” in the enable register).
6
RQS
64
The power supply is requesting service (serial poll).
7
Not used
0
Always set to 0.
5.3 IEEE488.2 Common Commands
Here’s a list and description of all common SCPI commands supported by the instrument.
*CLS
This command clears the following registers:
Standard event register
Query event register
Operation event register
Status byte register
Error code
Command syntax: *CLS
Parameter: None
*ESE
This command can set the parameter of standard event enable register. Setting parameter can
determine which bit of standard event register is 1 and the byte will enable ESB of status byte
register as 1.
Command syntax: *ESE <NR1>
Parameter: 0~255
The value when power on: Refer to *PSC command
Example: *ESE 128
Query syntax: *ESE?
Returned parameter: <NR1>
The bit definition of the standard event enabled register:
Bit
Position
7
6
5
4
3
2
1
0
Bit Name
PON
Not
used
CME
EXE
DDE
QYE
Not
used
OPC
Bit Weight
128
32
16
8
4
1
PON Power-on
CME Command error
EXE Execution error
w ww . . co m
information@itm.com1.800.561.8187

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision 9205 and is the answer not in the manual?

BK Precision 9205 Specifications

General IconGeneral
BrandBK Precision
Model9205
CategoryPower Supply
LanguageEnglish

Related product manuals