Example:
Request for CPU 43 with 50 CPUs in total
0x1B 0x5B 0x53 0x09 0x00 0x32 0x00 0x2B 0x00
Table 6-20. Return of CON (Input) for CPU (Output) with a fixed CPU number.
Bytes Description Coding
1 Control character 0x1B
1 Server identification 0x5D
1 Command 0x53
2 Total length of telegram (7 bytes, binary) 0x07 0x00
2 Total number of CPUs 0x01 0x00 (for 1 CPU) to 0x11F 0x00 (for 287 CPUs)
Example:
Return of Console 23 for CPU 43 with 50 CPUs in total
0x1B 0x5D 0x53 0x07 0x00 0x32 0x00 0x2B 0x00 0x17 0x00
Table 6-21. Connection of CON (input) with CPU (output)
with a fixed total CPU number.
Bytes Description Coding
1 Control character 0x1B
1 Server identification 0x5B
1 Command 0x54
2 Total length of telegram (7 bytes, binary) 0x07 0x00
2 Total number of CPUs 0x01 0x00 (for 1 CPU) to 0x11F 0x00 (for 287 CPUs)