FOCUS 1.9 Fault messages
Page 32 BOGE FOCUS compressor control for piston compressors
1.9 Fault messages
List of fault messages
Fault no. Meaning Compressor
switch-off
2 Motor temperature too high X
3 Fan motor X
5 Compressor system pressure too high X
6 Suction filter differential pressure too high
9 No output
10 Motor servicing due
11 Compressor servicing due
12 System pressure decrease too slow
14 Temperature too low (<37°F) X
16 Net pressure transmitter faulty X
18 Fault of an external control
19
Power-up phases too short, too many motor switching
cycles
20 Continuous contact of an external control
21 Receiver servicing due
22 Inner hood temperature too high
Parameterizable
(P032)
23 Cylinder head temperature too high X
24 Oil level too low
Parameterizable
(P044)
25 Data reconciliation error
1st warning,
then fault
26 Control unit OFF key does not open X
27 Control unit ON key does not open X
28 Control unit INFO key does not open
29 Control unit ENTER key does not open X
30 Control unit UP key does not open
31 Control unit DOWN key does not open
32 Net pressure transmitter wire breakage X