Event log recall mode
This function allows users to playback the last 254 events saved
in each event log on the text keypad.
All Event Log all events are logged
EN Event Log only mandatory EN 50131-3 events are
logged
Dialer Event Log only mandatory EN 50136 events are logged
How to select all event log recall mode
1. Enter your code + [2] [2] and press [#].
The system beeps twice and the event logs are displayed.
2. Use [▲] and [▼] to display all event logs.
3. Press [#] to exit.
How to select EN event log recall mode
1. Enter your code + [2] [3] and press [#].
The system beeps twice and EN event logs are displayed.
2. Use [▲] and [▼] to display all EN event logs.
3. Press [#] to exit.
How to select dialer event log recall mode
1. Enter your code + [2] [4] and press [#].
The system beeps twice and dialer events are displayed.
2. Use [▲] and [▼] to display all dialer event logs.
3. Press [#] to exit.