164 en | User Configuration Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
9.4.17 Cycle Door
Default:
Authority Levels 1, 2, 15: Enabled (E)
Authority Levels 3-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows the user with this authority level to cycle a door from any keypad
assigned to an area where the user has authority.
Press the keypad number keys [1 through 8] that correspond to the door number to cycle
doors. For example, pressing the 2 and the ENTER keys cycles door number 2, which is
indicated by "C" in the display.
RPS Menu Location
User Configuration > Authority Levels > Cycle Door
9.4.18 (Un)Lock door
Default:
Authority Levels 1, 2, 15: Enabled (E)
Authority Levels 3-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
Press the keypad number keys [1 through 8] that correspond to the door number to unlock/
relock doors. For example, pressing the 2 and the ENTER keys unlocks door number 2, which
is indicated by "U" in the display.
Authority Level 15 is reserved for the Service Passcode (User 0). You cannot change any
settings in the Authority Level 15 column.
RPS Menu Location
User Configuration > Authority Levels > (Un)Lock Door
9.4.19 Secure Door
Default:
Authority Levels 1, 15: Enabled (E)
Authority Levels 2-14: Blank (-)
Selections:
– Blank(-): This function is not authorized for the user who is assigned this authority level.
– Enabled (E): This function is authorized for the user who is assigned this authority level.
This parameter allows the user with this authority level to secure a door from any keypad
assigned to an area where the user has authority.
Press the keypad number keys [1 through 8] that correspond to the door number to secure/
unsecure doors. For example, pressing the 2 and the ENTER keys secures door number 2,
which is indicated by an "X" in the display.
Authority Level 15 is reserved for the Service Passcode (User 0). You cannot change any
settings in the Authority Level 15 column.
RPS Menu Location
User Configuration > Authority Levels > Secure Door

Table of Contents

Other manuals for Bosch B8512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B8512G and is the answer not in the manual?

Bosch B8512G Specifications

General IconGeneral
ModelB8512G
CategoryControl Panel
Power Supply12 VDC
SeriesG Series
Areas8
PGM Outputs on Board8
On-board EthernetYes
Wireless SupportYes
ManufacturerBosch
Input Voltage16.5 VAC
Users500
Communication FormatsIP, GSM, PSTN
CompatibilityCompatible with Bosch detectors, keypads, and communication modules