204 en | Points Control Panel
2017.03 | 09 | F.01U.303.998 Program Entry Guide Bosch Security Systems, Inc.
When a user turns an area Part On only Part On points are armed. Interior points, and Interior
Follower points are not armed. In a typical system, turning an area Part On arms only the
perimeter protection allowing users to remain in the premises without creating alarm events
from interior points.
10.4.3 Interior
Configuring a point profile with the Interior point type makes it an Interior point profile. Points
assigned to an Interior point profile are Interior points. Interior points are typically used to
monitor interior detection devices such as interior doors, motion detectors, photoelectric
beams, or carpet mats.
Interior points are armed only when the area is All On. They are not armed when the area is
Part On.
The Point Response, page 184 for Interior points can be configured for instant or delayed alarm
response.
– Instant - points configured for instant alarm response create alarm events immediately,
even during entry or exit delay time. Interior points are commonly configured for instant
alarm response.
– Delayed - when an interior point configured for delayed alarm response is tripped while
the area is All On, it initiates entry delay time. It will not create an alarm event unless
entry delay time expires before the area is turned off.
If the area is already in entry delay when an interior point with delayed alarm response
trips, the control panel compares the remaining entry delay time to the entry delay time
programmed for the interior point. If the interior point's entry delay time is less than the
remaining time, it shortens the entry delay time
Delayed points can also initiate an entry tone at the keypad (Refer to Entry Tone Off, page
191).
Notice!
Use the Interior Follower, page 204 profile for instant alarm if the area is not in entry delay
For some installations you may want an interior point that follows, but can not initiate entry
day. Tripping an Interior Follower point while the area is All On creates an instant alarm
event. However, if another point is tripped starting entry delay, and then the Interior Follower
point is tripped, the Interior Follower point delays the alarm response until exit delay time
expires. If the area is turned Off before entry delay time expires there is no alarm response.
10.4.4 Interior Follower
Configuring a point profile with the Interior Follower point type makes it an Interior Follower
point profile. Points assigned to an Interior Follower point profile are Interior Follower points.
Interior Follower points are typically used to monitor interior detection devices such as
interior doors, motion detectors, photoelectric beams, or carpet mats.
Interior Follower points are armed only when the area is All On. They are not armed when the
area is Part On.
Interior Follower points follow, but can not initiate entry day. Tripping an Interior Follower
point while the area is All On creates an instant alarm response. However, if another point is
tripped starting entry delay, and then the Interior Follower point is tripped, the Interior
Follower point delays the alarm response until exit delay time expires. If the area is turned Off
before entry delay time expires there is no alarm response
During Exit Delay, faulting an Interior Follower point does not create an alarm event (even if a
Part On, Delay point is not faulted during the exit delay).

Table of Contents

Other manuals for Bosch B8512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B8512G and is the answer not in the manual?

Bosch B8512G Specifications

General IconGeneral
ModelB8512G
CategoryControl Panel
Power Supply12 VDC
SeriesG Series
Areas8
PGM Outputs on Board8
On-board EthernetYes
Wireless SupportYes
ManufacturerBosch
Input Voltage16.5 VAC
Users500
Communication FormatsIP, GSM, PSTN
CompatibilityCompatible with Bosch detectors, keypads, and communication modules