EasyManuals Logo

Bosch B8512G Program Entry Guide

Bosch B8512G
284 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
Control Panel SDI2 modules | en 243
Bosch Security Systems, Inc. Program Entry Guide 2017.03 | 09 | F.01U.303.998
– Yes – open port forwarder using UPnP
– No – do not use UPnP.
When this parameter is set to Yes, the control panel sends a request to the premises router to
open a port forwarder. The port forward allows inbound RPS and RSC (Remote Security
Control) connections.
The UPnP parameter has no effect on event reporting to a central station receiver.
Notice!
UPnP requires IP Address / Host Name and Panel Port be configured
In the Panel Data – View, Network tab, verify that the IP Address / Host Name and Panel Port
parameters are configured.
The UPnP parameter has no effect on B450 Plug-in Communicator Interface operation.
RPS Menu Location
SDI2 > B42x IP Communicator > UPnP enable
14.4.10 HTTP Port Number
Default: 80
Selections: 1 to 65535
This parameter allows the configuration of the web server port number.
When TLS Enhanced Security is enabled, HTTPS is applied. The default value for HTTPS is 443.
If enhanced security is not enabled, the HTTP value is applied.
RPS Menu Location
SDI2 Modules > IP Communicator > HTTP Port Number
14.4.11 ARP Cache Timeout (sec.)
Default: 600
Selections: 1 to 600 (seconds)
This parameter specifies the time-out for ARP cache entries (time-out value in seconds).
The parameter has no effect on B450 Plug-in Communicator Interface operation.
RPS Menu Location
SDI2 > B42x IP Communicator > ARP cache timeout
14.4.12 Web/USB Access Enable
Default: No
Selections: Yes/No
This parameter enables authorized users to view and modify the B42x configuration
parameters through a standard web browser.
RPS Menu Location
SDI2 Modules > IP Communicator > Web/USB access Enable.
14.4.13 Web/USB Access Password
Default: B42V2
Selections: blank, ASCII printable characters
This parameter sets the password required to log in for web access.
The password must be 4-10 ASCII printable characters in length. Blank spaces disable the
password checking.
RPS Menu Location
SDI2 > IP Communicator > Web Access Password

Table of Contents

Other manuals for Bosch B8512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B8512G and is the answer not in the manual?

Bosch B8512G Specifications

General IconGeneral
ModelB8512G
CategoryControl Panel
Power Supply12 VDC
SeriesG Series
Areas8
PGM Outputs on Board8
On-board EthernetYes
Wireless SupportYes
ManufacturerBosch
Input Voltage16.5 VAC
Users500
Communication FormatsIP, GSM, PSTN
CompatibilityCompatible with Bosch detectors, keypads, and communication modules