EasyManua.ls Logo

Bosch CL6001iU W 26 E - Explanation of Symbols and Safety Instructions; Explanation of Symbols

Bosch CL6001iU W 26 E
192 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of contents
49
Climate 6000i – 6721838270 (2021/08)
Table of contents 1 Explanation of symbols and safety instructions
1.1 Explanation of symbols
Warnings
In warnings, signal words at the beginning of a warning are used to
indicate the type and seriousness of the ensuing risk if measures for
minimizing danger are not taken.
The following signal words are defined and can be used in this document:
DANGER
DANGER indicates that severe or life-threatening personal injury will
occur.
WARNING
WARNING indicates that severe to life-threatening personal injury may
occur.
CAUTION
CAUTION indicates that minor to medium personal injury may occur.
NOTICE
NOTICE indicates that material damage may occur.
Important information
The info symbol indicates important information where there is no risk to
people or property.
Table 1
1 Explanation of symbols and safety instructions . . . . . . . . . .49
1.1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . .49
1.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . .50
1.3 Notices regarding these instructions. . . . . . . . . . . . . . .50
2 Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
2.1 Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . .51
2.2 Scope of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
2.3 Product dimensions and minimum clearances. . . . . . .51
2.3.1 Indoor unit and outdoor unit . . . . . . . . . . . . . . . . . . . . .51
2.3.2 Refrigerant pipes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
2.4 Information on refrigerant . . . . . . . . . . . . . . . . . . . . . . .51
3 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
3.1 Before installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
3.2 Requirements for installation site . . . . . . . . . . . . . . . . .51
3.3 Unit installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
3.3.1 Installing the indoor unit . . . . . . . . . . . . . . . . . . . . . . . .52
3.3.2 Installing the outdoor unit . . . . . . . . . . . . . . . . . . . . . . .52
3.4 Pipework connection . . . . . . . . . . . . . . . . . . . . . . . . . . .52
3.4.1 Connecting refrigerant lines to the indoor and
outdoor unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
3.4.2 Connecting condensate pipe to the indoor unit . . . . . .53
3.4.3 Checking tightness and filling the system. . . . . . . . . . .53
3.5 Electrical connection . . . . . . . . . . . . . . . . . . . . . . . . . . .53
3.5.1 General notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
3.5.2 Connecting the indoor unit . . . . . . . . . . . . . . . . . . . . . .53
3.5.3 Connecting the outdoor unit . . . . . . . . . . . . . . . . . . . . .54
4 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
4.1 Commissioning checklist . . . . . . . . . . . . . . . . . . . . . . . .54
4.2 Functional test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
4.3 Handover to the user . . . . . . . . . . . . . . . . . . . . . . . . . . .54
5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
5.1 Faults with indication . . . . . . . . . . . . . . . . . . . . . . . . . . .54
5.2 Faults without indication . . . . . . . . . . . . . . . . . . . . . . . .55
6 Environmental protection and disposal . . . . . . . . . . . . . . . . .56
7 Data Protection Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
8 Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Symbol Meaning
Warning regarding flammable substances: the R32
refrigerant used in this product is a gas with mild
combustibility and low toxicity (A2L or A2).
Maintenance by a qualified person should be done
while following the instructions of the service manual.
For operation follow the operating instructions for
users.