EasyManua.ls Logo

Bosch CL6001iU W 26 E - Technical Data

Bosch CL6001iU W 26 E
192 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
57
Climate 6000i – 6721838270 (2021/08)
8Technical Data
Table 12
Set CL6001i-Set 26 E CL6001i-Set 35 E CL6001i-Set 53 E CL6001i-Set 70 E
Indoor unit CL6001iU W 26 E CL6001iU W 35 E CL6001iU W 53 E CL6001iU W 70 E
Outdoor unit CL6001i 26 E CL6001i 35 E CL6001i 53 E CL6001i 70 E
Cooling
Rated output kW
kBTU/h
2.6
9
3.5
12
5.3
18
7.0
24
Power input at rated output W 570
8
80 1290
1
760
Output (min. - max.) kW 1.32-3.81 1.32-3.96 1.99-6.13 2.11-8.21
Power input (min. - max.) W 130-1200 130-1250
160-1787
420-3200
Cooling load (Pdesignc) kW 2.6 3.5 5.3 7.0
Energy efficiency (SEER) 8.6 8.5 8.5 8.5
Energy efficiency class A+++ A+++ A+++ A+++
Heating – general
Rated output kW
kBTU/h
3.0
10.5
3.9
13.5
5.6
19
7
.3
25.5
Power input at rated output W 660
9
90 1510
1
975
Output (min. - max.) kW 0.88-4.4 0.88-4.54
1
.35-6.77 1.55-8.21
Power input (min. - max.) W 120-1400 120-1450
230-1695
300-3100
Heating – average climate
Heating load (Pdesignh) kW 2.4 2.4 4.3 5.0
Energy efficiency (SCOP) 4.6 4.6 4.3 4.2
Energy efficiency class A++ A++ A+ A+
Heating – warmer climate
Heating load (Pdesignh) kW 2.5 2.5 4.3 5.5
Energy efficiency (SCOP) 5.1 5.1 5.4 5.3
Energy efficiency class A+++ A+++ A+++ A+++
General
Power supply V / Hz 220-240 / 50 220-240 / 50 220-240 / 50 220-240 / 50
Max. power consumption W 2300 2300 2800 3700
Max. current consumption A 10.5 10.5 13 19
Refrigerant R32 R32 R32 R32
Refrigerant charge g 690 690 1100 1500
Design pressure (liquid side/gas side) MPa 4.3/1.7 4.3/1.7 4.3/1.7 4.3/1.7
Indoor unit
Blast-proof ceramic fuse on PCB T3.15A/250V T3.15A/250V T3.15A/250V T3.15A/250V
Air flow rate (high/medium/low) m
3
/h 530/360/280 560/380/290 685/580/400 1092/724/379
Sound pressure level (high/medium/low/
noise reduction)
dB(A) 37/32/21.5/20.5 40/33/22/21 41/35/23/22
4
4.5/40/33/21
Sound power level dB(A) 58 59 59 65
Permissible ambient temperature
(cooling/heating)
°C 16...32/0...30 16...32/0...30 16...32/0...30 16...32/0...30
Net weight kg 10.2 10.2 12.3 20
Outdoor unit
Blast-proof ceramic fuse on PCB T20A/250V T20A/250V T30A/250V T30A/250V
Air flow rate m
3
/h 2200 2200 3500 3500
Sound pressure level dB(A) 57 57.5 56 58.5
Sound power level dB(A) 64 65 65 68
Permissible ambient temperature
(cooling/heating)
°C –15...50/–15...24 –15...50/–15...24 –15...50/–15...24 –15...50/–15...24
Net weight kg 28.4 28.4 38.8 45.6

Table of Contents

Related product manuals