6 720 821 651 (2017/05) CRC200
6 | Product Description
2.2 Important instructions for use
• The user interface may be connected only to heat sources
with Bosch EMS-BUS or CZM100 for multi-zone
applications.
• This user interface is intended only for wall-mounted
installation ( Chapter 3, starting at page 7).
2.3 Scope of delivery
Fig. 3 Scope of delivery
[1] User interface
[2] Technical documentation
[3] Screws and anchors
WARNING: Risk of scalding!
▶ If hot water temperatures are set above
140 °F (60 °C) or thermal disinfection is
switched on, a mixer must be installed.
NOTICE: Risk of damage to the floor!
▶ Radiant floor heating must be installed
only as a heating zone with mixer and an
additional temperature switch to protect
the floor from overheating, by delivering
too hot supply water.
6 720 811 156-02.1O