Bosch DX025 - Unit Check-Out Sheet

Bosch DX025
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...


6720220327
Revised 11-11 Subject to change without prior notice

Customer Data
Customer Name ________________________________________________ Date __________________________________
Address ________________________________________________________
__________________________________________________________________
Phone __________________________________________________________ Unit Number _________________________
Unit Nameplate Data
Unit Make ______________________________________________
Model Number _________________________________________ Serial Number_______________________________
Refrigerant Charge (oz) _____________________
Compressor: RLA ____________________ LRA ______________
Blower Motor: FLA (or NPA) __________ HP _______________
Maximum Fuse Size (Amps) ________________
Minimum Circuit Ampacity (Amps) _________
Operating Conditions
Cooling Mode Heating Mode
Entering / Leaving Air Temp
______________ / _____________ ______________ / _____________
Entering Air Measured at:
_______________________________ ______________________________
Leaving Air Measured at:
_______________________________ ______________________________
Entering / Leaving Fluid Temp
______________ / _____________ ______________ / _____________
Fluid Flow (gpm)
_______________________________ ______________________________
Fluid Side Pressure Drop
_______________________________ ______________________________
Suction / Discharge Pressure (psig)
______________ / _____________ ______________ / _____________
Suction / Discharge Temp
______________ / _____________ ______________ / _____________
Suction Superheat
_______________________________ ______________________________
Entering TXV / Cap Tube Temp
_______________________________ ______________________________
Liquid Subcooling
_______________________________ ______________________________
Compressor Volts / Amps
______________ / _____________ ______________ / _____________
Blower Motor Volts / Amps
______________ / _____________ ______________ / _____________
Auxiliary Heat
Unit Made ______________________________________________________
Model Number _________________________________________________ Serial Number ________________________
Max Fuse Size (Amps) __________________________________________
Volts / Amps ____________________________________________________
Entering Air Temperature _______________________________________
Leaving Air Temperature
Bosch group 601 N.W. 65th Court, Ft. Lauderdale, FL 33309
Phone: 954-776-5471 Fax: 954-776-5529