Commissioning
MS 200 – 6720879925 (2017/11)
31
5. To complete the solar system configuration:
Confirm the current system configuration.
Solar configuration completed...
4.4 Overview of the service menu
The menus depend on the installed user interface and the installed
system.
Service menu
Commissioning
...
Solar settings
Solar thermal sys installed
Change solar configuration
Current solar configuration
Solar parameters
Solar circuit
Speed ctrl. solar pump
(Solar pump 1 solar circuit speed, collector array)
Min. speed solar pump
(Minimal speed of solar pump 1, collector array)
Switch-on diff. solar pump
(ON temperature differential, solar pump 1 collector array)
Switch-off diff. solar pump (Cut-out temperature differential,
solar pump 1 collector array)
Speed ctrl solar pump2
(Solar pump 2 circuit speed, collector array)
Min. speed solar pump 2
Switch-on diff. sol. pump2
(ON temperature differential, solar pump 2 collector array)
Switch-off diff. sol. pump2
(OFF temperature differential, solar pump 2 collector array)
Max. collector temp. (Maximum collector temperature)
Min. collector temp. (Minimum collector temperature)
Vac. tube pump anti-seize
(Vacuum tube collector, pump anti-seize 1 collector array)
Vac. tube pump kick 2
(Vacuum tube collectors, pump anti-seize 2 collector array)
Southern Europe function
Switch-on temp. S.Eur. fct.
(Switch-ON temperature Southern Europe function)
Collector cooling function
Cylinder
Max. temp. cyl. 1 (Cylinder 1 maximum temperature)
Max. temp. cyl. 2 (Cylinder 2 maximum temperature)
Max. pool temp. (Maximum swimming pool temperature)
Max. temp. cyl. 3 (Cylinder 3 maximum temperature)
Priority cylinder
Test interval priority cyl. (Test interval priority cylinder)
Test duration priority cyl. (Test duration priority cylinder)
Elapsed time valve cyl. 2
(Running time 3-way valve between 1st and 2nd cylinders)
Switch-on diff. heat ex.
(Temperature differential heat exchanger)
Switch-off diff. heat ex.
(OFF temperature differential heat exchanger)
Frost prot. temp. heat ex. (Frost threshold heat exchanger)
Central heating backup
Start diff. ctrl. heat back.
(ON temperature differential for central heating backup)
End diff. ctrl. heat. back.
(OFF temperature differential for central heating backup)
Max. mixer temp. CH
(Max. mixer temperature for central heating backup)
1.
2.
3.
4.
5.
ok
ok
ok
ok

Table of Contents