FLEXIDOME IP starlight 8000i Preparing for installation | en 13
Bosch Security Systems B.V.
Installation manual
2024-02 | V02 | F.01U.404.121
4.3 Wiring
1 10-pin I/O connector. 2 2-pin 24VAC / 12-26VDC power input
connector.
3 RJ45 network connector.
4.3.1 Network and PoE power
Connect the camera to a 10/100 Base-T network:
– Use STP Category 5e (or higher) cable with RJ45 connectors (the camera network
socket is AutoMDIX compliant).
– Power can be supplied to the camera via the Ethernet cable compliant with the Power-
over-Ethernet standard and/or via the 24VAC / 12-26VDC auxiliary power.
Notice!
Use only PoE approved devices.
Power-over-Ethernet (PoE) can be connected at the same time as a 24VAC / 12-26VDC
power supply. If auxiliary power (24VAC / 12-26VDC) and PoE is applied simultaneously,
the camera draws its power from PoE by default, and seamlessly switches to auxiliary input
if PoE power fails.