EasyManua.ls Logo

Bosch FLEXIDOME IP starlight 8000i - 4.3.1 Network and PoE power; 4.3.2 24 V AC; 12-26 V DC power input

Bosch FLEXIDOME IP starlight 8000i
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14 en | Preparing for installation FLEXIDOME IP starlight 8000i
2024-02 | V02 | F.01U.404.121
Installation manual
Bosch Security Systems B.V.
When PoE power returns, the camera seamlessly switches back to PoE as its default power
source.
4.3.2 24V AC / 12-26V DC power input
Connect a SELV-LPS or a SELV Class2 power supply with a rated supply voltage of 24VAC
or 12-26VDC.
i
Notice!
When using a 24VAC power supply, do not make a ground connection with one of the
24VAC supply leads. This will damage the camera.
4.3.3 10-pin I/O connector
Pin Connection
1 +12VDC out
2 GND
3 ALARM OUT
4 ALARM OUT
5 GND
6 ALARM IN 1
7 ALARM IN 2
8 GND
9 AUDIO IN
10 AUDIO OUT
12VDC power output
The 12VDC output can be enabled/disabled via the web interface, and controlled via the
Alarm Task Editor.
Maximum load of 50mA.
Alarm I/O
1. Input:
Use the alarm input to connect external alarm devices such as door contacts or
sensors:
TTL logic, +5V nominal, +40VDC maximum, DC coupled with 50kOhm pull-up to
+3.3V.
Configurable as active low or active high.
Use a zero potential make-contact or switch as the actuator (with a bounce-free contact
system).
2. Output:
Use the alarm output for switching external devices such as lamps or sirens. The alarm
output switching capability has a maximum voltage of 30VAC or +40VDC; maximum
0.5A continuous, 10VA.

Related product manuals