EasyManua.ls Logo

Bosch ICP-CC408 - Table 46: Point ID Codes; Table 47: Contact ID Format Breakdown

Bosch ICP-CC408
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ICP-CC408 | Installation Guide | 10.0 Dialer Reporting Formats EN | 47
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Table 46: Point ID Codes
Point ID Event Description Event Code Explanation Section
Zones 1 to 8 Burglary Zone 130 Burglary 14.3.2
Medical Zone 100 24-Hour Medical 14.3.2
Panic Zone 120 24-Hour Panic 14.3.2
Hold-Up Zone 122 24-Hour Hold-Up 14.3.2
Tamper Zone 137 24-Hour Tamper 14.3.2
Burglary Zone 133 24-Hour Burglary 14.3.2
Fire 110 24-Hour Fire 14.3.2
User Specific 1 to 16 Open/Close Report 401
Opening – User #
Closing – User #
15.7
040 AC MAINS Fail 301 AC Power 15.15
031 Low Battery 309 Battery Test Failure 15.17
User Specific 1 to 16 Codepad Duress 121 Duress Alarm 15.8
041 Codepad Panic 120 Panic Alarm 15.9
046 Codepad Fire 110 Fire Alarm 15.10
045 Codepad Medical 100 Medical Alarm 15.11
042 Code Retry Limit Exceeded 421 Access Denied 15.19
044 Test Report 602 Test Report 15.21
047 Test Report 602 Test Report 18.5
Zone Specific 1 to 8 Sensor Watch 307 Sensor Self Test Failure 15.3
Zone Specific 1 to 8 Trouble 380 Sensor Trouble 15.2
Zone Specific 1 to 8 Bypass 570 Zone Bypass 15.1
00 AUX Power Supply Fail 300 System Trouble 15.13
Table 47: Contact ID Format Breakdown
Subscriber ID
Number
Qualifier
Event Code
Group Number
Point ID Number
SSSS Q XYZ GG CCC
Four-digit
Subscriber ID
Number
Event Qualifier, which provides
specific event information:
1 – New event or opening
3 – New restore or closing
Event Code
(comprised of three
hex digits)
Group Number
(comprised of two
hex digits)
Point ID Number
(comprised of
three hex digits)

Table of Contents