ICP-CC408 | Installation Guide | 14.0 Zone Information EN | 58
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
14.3 Zone Programming
The programming information for each zone is
stored in seven locations divided into three groups.
The first three locations determine how the zone
operates, the next two locations set up a number of
zone options, and the last two locations store the
dialer reporting information for the zone.
Zone Operating Information
These locations store the Zone Type (for example,
Delay-1, Instant, or 24-Hour), the Zone Pulse Count,
and the Zone Pulse Count Time. The Zone Pulse
Count specifies the number of times the zone must
activate within the time specified in the Zone Pulse
Count Time. Refer to Sections 14.3.2 Zone Types,
14.3.3 Zone Pulse Count on page 60, and 14.3.4 Zone
Pulse Count Time on page 58 for more information.
Zone Options
These two locations allow you to select from a
number of options. Refer to Sections 14.3.5 Zone
Options 1 on page 60 and 14.3.7 Zone Options 2 on
page 62 for more information.
Zone Reporting Information
This information includes the locations for the Zone
Report Code and the Zone Dialer Options.
The Zone Report Code determines whether the
control panel sends Alarm Reports for the zone.
Refer to Section 14.3.8 Zone Report Code on page 63
for more information.
The Zone Dialer Options location enables you to
specify how a zone reports to a base station receiver.
Refer to Section 14.3.9 Zone Dialer Options on page 63
for more information.
14.3.1 ICP-CC408 Zone Defaults
Location
267 to 322
Location Default
Zone #01 (Default = Delay–1)
Zone Type 267 2
Zone Pulse Count 268 0
Zone Pulse Count Time 269 0
Zone Options 1 270 1
Zone Options 2 271 14
Report Code 272 1
Dialer Options 273 1
Zone #02 (Default = Handover)
Zone Type 274 1
Zone Pulse Count 275 0
Zone Pulse Count Time 276 0
Zone Options 1 277 1
Zone Options 2 278 14
Report Code 279 1
Dialer Options 280 1
Location
267 to 322 (continued)
Zone #03 (Default = Handover)
Zone Type 281 1
Zone Pulse Count 282 0
Zone Pulse Count Time 283 0
Zone Options 1 284 1
Zone Options 2 285 14
Report Code 286 1
Dialer Options 287 1
Zone #04 (Default = Handover)
Zone Type 288 1
Zone Pulse Count 289 0
Zone Pulse Count Time 290 0
Zone Options 1 291 1
Zone Options 2 292 14
Report Code 293 1
Dialer Options 294 1
Zone #05 (Default = Instant)
Zone Type 295 0
Zone Pulse Count 296 0
Zone Pulse Count Time 297 0
Zone Options 1 298 1
Zone Options 2 299 14
Report Code 300 1
Dialer Options 301 1
Zone #06 (Default = Instant)
Zone Type 302 0
Zone Pulse Count 303 0
Zone Pulse Count Time 304 0
Zone Options 1 305 1
Zone Options 2 306 14
Report Code 307 1
Dialer Options 308 1
Zone #07 (Default = Instant)
Zone Type 309 0
Zone Pulse Count 310 0
Zone Pulse Count Time 311 0
Zone Options 1 312 1
Zone Options 2 313 12
Report Code 314 1
Dialer Options 315 1
Zone #08 (Default = 24-hr. Tamper)
Zone Type 316 9
Zone Pulse Count 317 0
Zone Pulse Count Time 318 0
Zone Options 1 319 1
Zone Options 2 320 12
Report Code 321 1
Dialer Options 322 1
You can program Zones 1 to 8 as any Zone Type.