ICP-CC408 | Installation Guide | 2.0 Programming EN | 15
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
2. Enter [9 6 1 #].
Two beeps sound after the control panel is
successfully defaulted.
3. Enter [9 6 0 #].
Two beeps sound. The STAY and AWAY
indicators stop flashing and the system returns to
the disarmed state.
The control panel is now successfully defaulted
back to the factory settings.
4. Press and hold the default button.
The default button is located at the top of the
PCB next to the PROGRAMMING KEY socket.
5. Enter [1 5 *] to program 15 into Location 900.
6. Release the default button.
7. Enter [9 6 0 #] to exit from Installer’s
Programming Mode.
Two beeps sound and the system returns to the
disarmed state.
If you are using a remote codepad, the STAY
and AWAY indicators are extinguished to
indicate the system is disarmed.
Table 7: Command 965 Defaults
Location Description Default Value Setting
032 Handshake Tone for Receiver 1
1 (Handshake Tone)
033 Transmission Format
4 (Domestic)
034 to 039 Subscriber ID Number
0, 0, 0, 0, 0, 1 (1 Beep)
332 Zone Status Reporting Options
2 (Receiver 2 only)
333 and 334 Open/Close Reports
11, 12 (Open/Close Reports)
335 Open/Close Reporting Options
2 (Receiver 2 only)
356 to 358 System Status – Access Denied
6, 7, 12 (Access Denied)
359 System Status Reporting Options
2 (Receiver 2 only)
360 to 366 Test Report Time
0, 0, 0, 0, 7, 1, 0 (Test Reports)
367 Test Reporting Dialer Options
1 (Receiver 1 only)
If Location 900 is not programmed as 15, do one of
the procedures below to successfully default the
control panel to the factory settings.
To default the control panel using the Installer
Code:
1. Enter the Installer Code (the default is 1234) and
press [#] to enter Installer’s Programming Mode.
Two beeps sound. The STAY and AWAY
indicators begin to flash to indicate you entered
Installer’s Programming Mode.
2. Enter [9 6 1 #].
Two beeps sound after the control panel is
successfully defaulted.
3. Enter [9 6 0 #].
Two beeps sound. The STAY and AWAY
indicators stop flashing and the system returns to
the disarmed state.
The control panel is now successfully defaulted
back to the factory settings.
To default the control panel using the default
button:
1. Disconnect the AC MAINS supply and the
backup battery from the control panel.
2. Press and hold the default button.
The default button is located at the top of the
PCB next to the PROGRAMMING KEY socket.
3. Reconnect the AC MAINS supply to the control
panel.
4. Wait 3 to 5 sec and release the default button.
5. Enter [2 5 8 0 *] to disarm the system using the
default Master Code.
The control panel is successfully defaulted to the
factory settings.
If the option to restore the default control
panel settings is disabled using Location
900:
• The dialer seize relay (RL2) clicks four
times. You must return the control
panel to Bosch Security Systems, Inc.
for exchange. If the Installer Code is
unknown, a service fee is charged to
unlock the control panel’s memory
• When programmed to disable the
default control panel setting, you
cannot use the command [961#] to
retrieve the programming data.
The use of this feature is not
recommended.