52 en | Configuration Integrus
IOM-INT | V1.1 | 2010.12 Installation and Operation manual Bosch Security Systems B.V.
7.2.3 Set network mode
The network mode menu item (4B) is used to enable and disable the optical network
connections. When the transmitter is connected to a DCN Next Generation conference
system, the optical network connections must be enabled.
7.2.4 Set number of channels
Via sub-menu item 4C the number of channels that will be used can be set. Note that the
maximum number of channels depends on the transmitter type (4, 8, 16 or 32 channels) and
the chosen quality modes. When a DCN Next Generation or a DCN system is connected to the
transmitter, the number of channels can be automatically set by the connected system.
- Aux to All The signals on the Auxiliary inputs are
distributed on one carrier to all channels.
- Test A A different test tone is distributed on each
channel. The frequency increases with
increasing channel number. For stereo
channels the tone for left and right will also be
different.
- Slave The radiator signal on the slave input is
looped-through to all radiators.
Menu Item Options Description
Menu Item Options Description
4B Network Mode Mode:
- Disabled Optical network connections disabled. Use
this mode when the transmitter is not used in
combination with DCN Next Generation.
- Enabled Optical network connections enabled. Use
this mode when the transmitter is used in
combination with DCN Next Generation.
Menu Item Options Description
4C Nr. of Ch. Nr. of channels