Fig�23: Installing the socket
6.6 Installing the socket
Installation position:
Various socket and plug installations are possible depending on the requirements.
Securing the socket to the frame
1. If they are not pre-drilled, make holes in the seals for the cables.
2. Guide all the cables through the compression screw (5), seal (4), socket housing (3) and flat gasket (6).
Observe the connection position for the connector when doing so.
3. Use an o-ring (2) and screw plug (1) to seal the unused opening in the socket housing.
Connecting the socket
4. Connect/solder the cable in the flanged socket (7). Make apin assignment diagram.
5. Attach the flanged socket to the socket housing (3).
6. Press in the seal (4) with the compression screw (5).
7. Engage the socket in the slot at the frame and fix in position with set screws.
8. Perform afunctional check. Follow the instructions in chapter 9 and 10.