Number Item Description
48 Telephone/Emergency level
adjustment
Adjusts the output level for the Telephone/Emergency signal applied to
inputs (46) and/or (47). This adjustment does not change the sensitivity
of the input gate (VOX).
55 Ducking level Attenuates the music level from the internal music source or Music
inputs 1-3 when the priority mute function is activated.
The ducking attenuation is adjustable in the range 0 to -60 dB.
Priority switches
Two switches (26) to set the Priority of inputs 1 to 6. The Telephone/Emergency input has
highest priority and always overrides all other inputs:
Switch setting Priority Remark
00 Serial: 1 > 2 > 3 > 4 > 5 > 6 Input 1 has highest
priority.
Input 6 has lowest
priority.
01 Block The first activated input
gets priority.
Other inputs are muted
(blocked).
10 Override The last activated input
gets priority.
The other inputs are
overridden.
11 Mix No priority.
All inputs are mixed.
Table 7.1: Priority switches settings
Chime switches
Two switches (27) to select the chime on input 1 for a PLE-1CS or PLE-1SCS. The PLN-6CS
call stations have their own chime selector:
Switch setting Chime Frequency
00 No chime
01 1-tone chime 554 Hz
10 2-tone chime 554/440 Hz
11 4-tone chime 294/392/495/588 Hz
Table 7.2: Chime switches settings