RADION receiver SD RADION TriTech | en 55
Bosch Security Systems B.V. 2020.05 | 13 | F.01U.261.834
During this test mode, motion detected within the detector’s
coverage area causes a transmitted alarm and LED activation.
Each alarm will also extend the Test Mode. Watch for the green
LED to indicate the edges of the Microwave pattern. Adjust as
necessary.
Please reference the LED table below for LED descriptions.
LED Condition Cause
Steady LED PIR activation (Walk Test)
Steady green Microwave activation
Steady blue Alarm signal
Flashing blue Warm-up period after power-up
No LED upon initial
power up
PIR failure. Replace unit.
Tab.6.9: LED description
Walking Testing the system
1. Start at the pattern’s expected boundary and walk across
the pattern moving closer to the detector. Set the
adjustment as low as possible for proper catch
performance.
2. Adjust the Microwave Range Adjustment Potentiometer to
as low a setting as possible for proper catch performance.