56 en | RADION TriTech RADION receiver SD
2020.05 | 13 | F.01U.261.834 Bosch Security Systems B.V.
Figure6.1: Sensitivity settings
Callout ᅳ Description
1 ᅳ Alarm LED (blue, green, or red)
2 ᅳ Microwave Range Adjustment Potentiometer
3. At each pass, observe the color on the Alarm LED (refer to
the Sensitivity settings figure above).
4. Walk test from the opposite direction to determine the
coverage pattern boundaries from both sides.
5. When walk test is completed, the detector returns to
normal operation after 90 sec of inactivity.