Bosch rexroth A21VG 10 Series - Above-reservoir installation

Bosch rexroth A21VG 10 Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
28/56 Installation
Bosch Rexroth Corporation, A21VG Series 10, RE 93223-01-B/09.2020
7.3.2 Above-reservoir installation
Above-reservoir installation means that the axial piston unit is installed above the
minimum uid level of the reservoir.
Observe the maximum permissible suction height h
Smax
=800mm.
The permissible suction height h
S
is derived from the total pressure loss.
3 4
X
1
, X
2
X
2
, R, X
1
h
t min
h
min
L
1
SB
T
h
t min
h
min
L
1
SB
T
Fig. 7: Above-reservoir installation A21VG without boost pump, installation position 3–4
L
1
Filling / air bleed
h
t min
Minimum required immersion depth
(200 mm)
R
Air bleed port
T
Reservoir port (case drain)
h
min
Minimum required spacing to
reservoir bottom(100mm)
SB
Bafe (bafe plate)
h
S max
Maximum permissible suction height
(800mm)
Table 9: Above-reservoir installation
Installation position Air bleeding the
housing
Air bleed
Stroking chamber
Filling
3 (drive shaft, horizontal) R* X
1
, X
2
L
1
+ X
1
+ X
2
4 (drive shaft, horizontal) L
1
L
1
* If R port is inaccessible, for installation position 1, the X
1
and X
2
ports can be opened to bleed
the air when the unit is not in use. Does not apply to HT units.