38/56 Installation
Bosch Rexroth Corporation, A21VG Series 10, RE 93223-01-B/09.2020
7.4.9 Electrically connecting the axial piston unit
NOTICE
Short circuit in event of penetrating hydraulic uid!
Fluid can penetrate the product and cause a short circuit!
▶ Do not install axial piston units with electric components (e.g. electric
controls, sensors) in a reservoir below the uid level (inside-reservoir
installation).
The machine/system manufacturer is responsible for the layout of the electric
control.
Electrically controlled axial piston units must be connected in accordance with the
electrical circuit diagram for the machine/system.
For axial piston units with electrical control and/or mounted sensors, please
comply with the details given in data sheet 93223, e.g.:
• the permissible voltage range
• the permissible current
• correct pin assignment
• the recommended electrical control units
Exact details on the connector, type of protection and matching mating connector
can also be found in data sheet 93223. The mating connector is not included in the
scope of supply.
1. Switch off power supply to the relevant system component.
2. Electrically connect the axial piston unit (12 or 24V). Before connecting, check
that the connector including all seals are intact.
If necessary, you can change the connector orientation by turning the solenoid
housing. This is dependent on the connector version.
To do this, proceed as follows:
1. Loosen the mounting nut (1) of the solenoid. To do this, turn the mounting nut
(1) one turn counterclockwise.
2. Turn the solenoid body (2) to the desired position.
3. Retighten the mounting nut. Tightening torque of the mounting nut: 5+1 Nm.
7.5 Performing ushing cycle
In order to remove foreign particles from the system, Bosch Rexroth recommends a
ushing cycle for the entire system before initial commissioning. To avoid internal
contamination, the axial piston unit must not be included in the ushing cycle.
The ushing cycle must be performed with an additional ushing unit. Follow
the instructions of the ushing unit’s manufacturer for the exact procedure
during the ushing cycle.
Changing connector
orientation
1
2