Safety instructions 11/56
RE 93223-01-B/09.2020, A21VG Series 10, Bosch Rexroth Corporation
2.6 Product-specic safety instructions
The following safety instructions apply for chapters 6 to 14.
WARNING
Danger from excessive pressure!
Danger tolife, risk ofinjury orproperty damage!
Improperly changing thefactory pressure settings can result inapressure
increase beyond themaximum permissible pressure.
Operating theunit above themaximum permissible pressure can cause
components toburst and hydraulic uid toescape under high pressure.
▶ Changes tothe factory settings may only bemade byBoschRexroth
specialists.
▶ Inaddition, apressure relief valve isrequired inthe hydraulic system
asback-up. If theaxial piston unit isequipped with apressure cut-off and/
or pressure controller, this isnot anadequate safeguard against pressure
overload.
Danger due tosuspended loads!
Danger tolife, risk ofinjury orproperty damage!
Improper transportation may cause theaxial piston unit tofall down and lead
toinjury, e.g. crushing orfracture, ordamage tothe product.
▶ Make sure that theload bearing capacity ofthelifting device issufcient
tosafely bear theweight oftheaxial piston unit.
▶ Never step orgrip under suspended loads.
▶ Ensure astable transport position.
▶ Use your personal protective equipment (e.g. safety goggles, safety gloves,
suitable working clothes, safety shoes).
▶ Use suitable lifting devices for transport.
▶ Observe theprescribed position ofthelifting strap.
▶ Observe thenational laws and specications ofoccupational safety and health
and transport.
System/machine under pressure!
Risk ofdeath orserious injury when working onunsecured machines/systems!
Property damage!
▶ Switch off theentire system and secure itagainst reactivation according tothe
parameters provided bythemachine/system manufacturer.
▶ Ensure that all relevant components ofthehydraulic system are depressurized.
For this purpose, observe theparameters indicated bythemachine/system
manufacturer.
▶ Please note that thehydraulic system might still bepressurized even after
separation from theactual pressure supply.
▶ Do not disconnect any line connections, ports andcomponents aslong
asthehydraulic system isunder pressure.