Bosch Rexroth Corp., USL00010, 01.2015
9 Power Supply
9.1 Congurepowersupply
9.1.1 Stepsforconguringthepowersupply:
1. In the Explorer tree, select Power Supply.
2. If drive is connected to:
3-phase mains supply: check box Phase monitoring of mains voltage.
1-phase mains supply: uncheck box Phase monitoring of mains voltage.
NOTE: For all CKL linear motor sizes, allowed mains supply 1- or 3-phase AC 110-230V
connected to drive. If a drive for higher voltage is used (e.g. 3 ~ 400V with HCS01.1E-
W00xx-A-03-…), please use a transformer and limit bleeder to 390V.