01.2015, USL00010, Bosch Rexroth Corp.
12 Motor (continued)
12.3CongurelinearmotorcontinuouscurrentforCKLsystem
12.3.1 StepsforconguringthelinearmotorcontinuouscurrentforCKLsystem:
1. Double-click parameter S-0-0111 in the parameter list.
2. Input the CKL value (see below table) and then press the Enter key.
System size Carriage length Primary part DB value Factor % CKL value
CKL 110 180 mm MCP030B-V180 1.3 75 0.98
240 mm MCP030C-V180 1.8 75 1.35
300 mm MCP030D-V180 2.5 75 1.88
CKL 145 244 mm MCP040C-V300 2.9 85 2.47
364 mm MCP040E-V300 4.7 85 4.00
484 mm MCP040G-V300 6.6 85 5.61
CKL 200 237 mm MCP070C-V300 5.1 82 4.18
297 mm MCP070D-V300 6.4 82 5.25
417 mm MCP070F-V300 9.0 82 7.38
3. Parameter S-0-0111 value is now updated in the drive for the specic CKL system size.
4. Close the Parameter editor.