EasyManua.ls Logo

Bosch rexroth ctrlX SAFETY SafeMotion - Safety bus communication

Bosch rexroth ctrlX SAFETY SafeMotion
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ctrlX SAFETY "SafeMotion"
Safety bus communication
Bosch Rexroth AG
R911404905,
Edition 02
Information, instructions and notes on the ctrlX AUTOMATION Community can
be found in the FAQ about the ctrlX AUTOMATION Community.
9.4
Safety bus communication
9.4.1
Brief description
Besides the discrete selection and acknowledgment, the integrated safety tech-
nology in the “Safe Motion“ characteristic supports the selection and acknowl-
edgment of the safety functions via safe channels of master communication
(Safety bus communication). For this purpose, the standard protocol of the
respective master communication is extended by a safe protocol. Thus, safe
information can be transmitted to and from a safety master, besides the
standard communication.
Features
The safety technology operating states of the active “Safe Motion“ profile
can be selected via the safety bus communication.
Direct selection (in parallel with the Safety bus communication) is possible.
The following safe protocol is supported:
FSoE FailSafe over EtherCAT (from AXS‑V‑0304)
Configurable connections are available in addition to the permanently prede-
fined configurations. Defined signals and generic control or status signals
can be configured in the configurable connections.
Only one control word and one status word with signals defined by the config-
uration type can be transmitted via the Safety bus communication (see “Con-
sumer and producer connection configuration”). Other process data, such as
safe position feedback values, are not available.
The bus communication type has to be selected in the configuration
(P‑0‑3345).
9.4.2
Functional principle
To use the Safety bus communication, it must be activated during commis-
sioning (P-0-3345). The safe protocol for safe communication is determined
upon activation.
The Safety bus communication can only be activated/deactivated in the "SMO
configuration mode (CM)".
Establishing a connection is possible in the “Parameterization mode (PM)” and
in the “Operating mode (OM)”.
The current status of the connection can be read via P‑0‑3342 (consumer con-
nection) and P-0-3343 (producer connection).
The Safety bus communication only supports one consumer connection and
one producer connection per drive. The active predefined configuration defines
which data are transmitted via these connections. The content and use of the
configurations are independent of the master communication and the safety
protocol via and with which the data are transmitted.
Selection and acknowledgment

Table of Contents