ctrlX SAFETY "SafeMotion"
13.3.2 XD03, motor connection
Important information
WARNING
Lethal electric shock due to live parts with more than 50
V!
Only operate the device
− with connected connectors (even if no lines are con-
nected to the connectors) and
−
with connected equipment grounding conductor!
NOTICE
Risk of damage to the device!
Provide strain relief for the terminals of the device in the
control cabinet.
Connectors
not included in scope of delivery.
Installation instructions
The specified connection cross sections are the cross sections that can be
connected. Size the required cross section of the connection lines according to
the occurring current load.
− Provide for optimum shield contact of the motor power cable.
−
For the connection between drive controller and motor, use our ready-made
motor power cables, where possible.