Motor connection: Overview
There are different types of connections:
● Screw connection at device ( ).
●
Screw connection at connector ( ).
●
Spring terminal at connector ( ).
The table below gives an overview of motor connections including the hybrid
connection XZ03.
Table 38: Motor connection: Overview
Component
PE + XD03
XD03
XZ03
1)
XCS 1×
0100, 0120: 35 mm
2
0150, 0180: 50 mm
2
02xx, 03xx: 120 mm
2
1×
0054, 0070: 10 mm
2
1×
0023: 10 mm
2
XCD - - 2×
0606…2323: 10 mm
2
XMS 1×
0100, 0120: 35 mm
2
0150, 0180: 50 mm
2
02xx: 120 mm
2
1×
0054, 0070: 10 mm
2
0090: 16 mm
2
1×
0006…0036: 10 mm
2
XMD - 2×
W5454, W7070: 10 mm
2
2×
0606…2323: 10 mm
2
PE + XD03: Screw connection at device
XD03: Screw connection at connector
XZ03: Spring terminal at connector
1) See ⮫ Chapter 13.3.1 XZ03, hybrid connection (motor, motor temperature monitoring and motor