ctrlX SAFETY "SafeMotion"
XD03, motor connection (10 mm
2
)
Table 39: Function, pin assignment, properties
View Identifica-
tion
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
For equipment grounding connection at motor
Screw connection at connector Unit min. max.
Connection cables
Stranded wire
mm
2
0.75 10.0
AWG 18 8
Stripped length mm 14
Tightening torque Nm 1.5 1.8
Occurring current load and minimum
required connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Includes short circuit protection A1, A2, A3 against each other and each of
them against ground
Shield connection accessories:
● XCS*-*0054/70: XAS2-006-003-NN;
●
XMS*-*0054/70: XAS2-005-003-NN;
Typical motor cable cross section: 1 × 6 mm
2