ctrlX SAFETY "SafeMotion"
Motor connections
Bosch Rexroth AG
R911404905,
Edition 02
XD03, motor connection (16 mm
2
)
Table 40: Function, pin assignment, properties
View Identification Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
For equipment grounding connection at
motor
Screw connection at connector Unit min. max.
1)
Connection cables
Stranded wire
mm
2
0.75 16.0
AWG 18 6
Stripped length mm 12
Tightening torque Nm 1.7 1.8
Occurring current load and minimum
required connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Includes short circuit protection A1, A2, A3 against each other and each of
them against ground
1) Ferrule only allowed without plastic sleeve.
Shield connection accessories:
XMS*-W0090: XAS2-005-003-NN;
Typical motor cable cross section: 1 × 10 mm
2