EasyManua.ls Logo

Bosch rexroth ctrlX SAFETY SafeMotion - Page 265

Bosch rexroth ctrlX SAFETY SafeMotion
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ctrlX SAFETY "SafeMotion"
Motor connections
Bosch Rexroth AG
R911404905,
Edition 02
XD03, motor connection (35 mm
2
)
Table 41: Function, pin assignment, properties
View Identifica-
tion
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
Connection block Unit min. max.
Connection cables
Stranded wire
mm
2
0.5 35
AWG 20 2
Stripped length mm 18
Tightening torque (≤ 25 mm
2
) Nm 2.5
Tightening torque (≥ 25 mm
2
) Nm 4.5
Occurring current load and minimum
required connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Includes short circuit protection A1, A2, A3 against each other and each of
them against ground
Cable feedthrough at the device:
Shield connection accessories:
XCS*-W0100/120: XAS2-002-003-NN;
Typical motor cable cross section: 1 × 16 mm
2
Double wiring with 2 × 10 mm
2
is possible using twin ferrule
Project planning

Table of Contents

Related product manuals