ctrlX SAFETY "SafeMotion"
XD03, motor connection (50 mm
2
)
Table 42: Function, pin assignment, properties
View Identifi-
cation
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
Terminal block Unit min. max.
Connection cable
Stranded wire with ring cable lug
1)
mm
2
1×50
2×25
AWG 1×1/0
Screw thread M6
Tightening torque Nm 4 5
Occurring current load and minimum
required connection cross section
See technical data of device used (I
LN
and A
LN
)
Occurring voltage load See technical data of device used (U
LN
or
U
LN_nenn
)
1) Maximum allowed length of ring cable lug: 38 mm; insulate ring cable lugs
with heat shrink sleeves
Shield connection accessories:
● XCS*-W0150/180:
–
XAS2-007-001-NN;
–
XAS2-007-002-NN;
●
XMS*-W0150/180:
– XAS2-008-001-NN;
– XAS2-008-002-NN;
Typical motor cable cross section: 1 × 16 mm
2
Double wiring with 2 × 10 mm
2
is possible using twin ferrule