ctrlX SAFETY "SafeMotion"
Motor connections
Bosch Rexroth AG
R911404905,
Edition 02
XD03, motor connection (120 mm
2
)
Table 43: Function, pin assignment, properties
View Identifi-
cation
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
Terminal block Unit min. max.
Connection cable
Stranded wire with ring cable lug
1)
mm
2
1×16, 2×16 1×120, 2×120
AWG 1×6, 2×6 1×4/0, 2×4/0
Screw thread M10
Tightening torque Nm 16 20
Occurring current load and minimum
required connection cross section
See technical data of device used (I
LN
and A
LN
)
Occurring voltage load See technical data of device used (U
LN
or
U
LN_nenn
)
1) Insulate ring cable lugs with heat shrink sleeves
Shield connection accessories:
XCS*/XMS*-W0210/250/280:
XAS2-004-001-NN;
XAS2-004-002-NN;
Typical motor cable cross section:
1 × 50 mm
2
Double wiring with 2 × 25 mm
2
is possible using twin ferrule
Project planning

Table of Contents