EasyManua.ls Logo

Bosch rexroth ctrlX SAFETY SafeMotion - Page 187

Bosch rexroth ctrlX SAFETY SafeMotion
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ctrlX SAFETY "SafeMotion"
First use
Bosch Rexroth AG
R911404905,
Edition 02
The polarity can only be set consistently for all scaling types (position,
velocity, acceleration).
Afterwards, the settings that were made have to be verified. (If the SMO
encoder parameters were applied from the standard firmware using the com-
mand, they only need to be verified in this dialog.)
With the parameter verification, it is necessary to check/verify whether the
parameterization active in the drive complies with the parameters intended or
configured for this axis.
The parameter verification is carried out in ctrlX DRIVE Engineeringvia the
bottom sections of the SafeMotion dialogs (“verification display”).
Go to the next commissioning dialog by using the “Next >>” button.
Standstill monitoring
In the Standstill monitoring dialog, set the velocity threshold (P–0–3255) below
which SafeMotion is to detect and signal standstill. Set the value so high that
the encoder noise does not exceed the value when the axis is at standstill.
Fig. 81: Standstill monitoring
Afterwards, the value that was set has to be verified.
With the parameter verification, it is necessary to check/verify whether the
parameterization active in the drive complies with the parameters intended or
configured for this axis.
The parameter verification is carried out in ctrlX DRIVE Engineeringvia the
bottom sections of the SafeMotion dialogs (“verification display”).
Go to the next commissioning dialog by using the “Next >>” button.
Commissioning

Table of Contents