ctrlX SAFETY "SafeMotion"
Table 64: FSoE status, detailed diagnostics
PF41
Green
Meaning/cause Remedy
Continuous light Normal; communication ok -
Jittering, alternately with 1
pulse
Error S-parameter (TwinSaf
parameter)
As reading out the blinking pat-
tern is very difficult, the drive
additionally generates the error
F3452 in case of these errors.
Check configuration and correct
it, if necessary. If error occurs
again in spite of correct configu-
ration, please contact our service
department; they can read out
the exact cause of error by
means of detailed diagnostics.
Jittering, alternately with 2
pulses
Error I-parameter (individual
parameters)
Jittering, alternately with 5
pulses
Watchdog error
Jittering, alternately with 6
pulses
CRC error
Jittering, alternately with 7
pulses
Sequential number error
Jittering, alternately with 8
pulses
Communication error