Short circuit protection A1, A2, A3 against each other and each of them against
ground
Connection of equipment grounding conductor
Via connection point of equipment grounding conductor at
device (see index entry "Connection → Equipment grounding
conductor")
Fig.5-6: Function, Pin Assignment, Properties
X5, Motor Connection HCS01.1E-W0018-x-03, -W0028-x-03
View Identifica‐
tion
Function
A1 For power connection U1 at motor
A2 For power connection V1 at motor
A3 For power connection W1 at motor
Screw connection at connector Unit Min. Max.
Connection cable
Stranded wire
mm
2
0,25 6,0
AWG 24 8
Stripped length mm 10
Occurring current load and minimum required
connection cross section
A See technical data of device used (I
out
)
Occurring voltage load V See technical data of device used (U
out
)
Short circuit protection A1, A2, A3 against each other and each of them against
ground
Connection of equipment grounding conductor
Via connection point of equipment grounding conductor at
device (see index entry "Connection → Equipment grounding
conductor")
Fig.5-7: Function, Pin Assignment, Properties
24/65 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth IndraDrive | Instruction Manual
Instructions for Use

Table of Contents