3 Ratings and Dimensions
UL Ratings and Dimensions
Description Symbol Unit
HCS0
1.1E-
W000
3-_-02
HCS0
1.1E-
W000
6-_-02
HCS0
1.1E-
W000
9-_-02
HCS0
1.1E-
W001
3-_-02
HCS0
1.1E-
W000
5-_-03
HCS0
1.1E-
W000
8-_-03
HCS0
1.1E-
W001
8-_-03
HCS0
1.1E-
W002
8-_-03
Listing according to UL standard
(UL)
UL 508 C
Listing according to CSA standard
(UL)
Canadian National Standard(s) C22.2 No. 14-05
UL files (UL) E 134201
Ambient temperature with nominal
data (UL)
T
amax
°C 40
Ambient temperature with reduced
nominal data (UL)
T
amax_red
°C 55
Mass (weight) m kg 0,72 1,70
Device height (UL)
1)
H mm 215 268
Device depth (UL)
2)
T mm 196
Device width (UL)
3)
B mm 50 70
Minimum distance on the top of the
device
4)
d
top
mm 100
Minimum distance on the bottom of
the device
5)
d
bot
mm 100
Horizontal spacing on the device
6)
d
hor
mm 10 0
Rated control voltage input (UL)
7)
U
N3
V 24 ± 5%
Rated power consumption control
voltage input at U
N3
(UL)
8)
P
N3
W 27 28 27 28 34
Short circuit current rating (UL) SCCR A rms 42000
Rated input voltage, power (UL)
9)
U
LN_nenn
V 3 x AC 110...230 3 x AC 200...500
Tolerance rated input voltage (UL) % ± 10
Input frequency (UL)
f
LN
Hz 50...60
Tolerance input frequency (UL) Hz ± 2
Rated input current (UL)
I
LN
A 0,6 1,2 2,3 4,5 1,5 2,5 5,0 10,0
Branch circuit protection fuse
(UL)
10)
2 4 6 2 4 10 16
Required wire size according to
EN 60204‑1
11)
A
LN
mm
2
1,5
Required wire size according to UL
508 A (internal wiring); (UL)
12)
A
LN
AWG AWG 14
Output voltage (UL)
U
out
V 3 x AC 0...230 3 x AC 0...500
Last modification: 2009-07-28
Instruction Manual | Rexroth IndraDrive Electric Drives
and Controls
| Bosch Rexroth AG 13/65
Ratings and Dimensions