Editing drive parameters
Fig.9-17: Drive parameter editor
Proceed as follows to edit a drive parameter:
1. Log in as OEM or Developer user.
2. Open the <System> operating area.
3. Press <F3> (DrivePar).
4. Press <TAB> to move to the parameter number input field.
5. Enter the desired parameter number (e.g., S100 or P12).
6. If necessary, switch the drive phase to <Phase2> using the machine keys.
7. Edit the parameter.
8. Switch the drive phase back to <Phase4>.
DOK-MTXMIC-EASY*******-CO04-EN-P
Rexroth IndraMotion MTX micro Easy setup for Standard Turning and Milling Machines
Bosch Rexroth AG 123/141
Operating the IndraMotion MTX micro