EasyManua.ls Logo

Bosch Rexroth IndraMotion MTX micro - Page 55

Bosch Rexroth IndraMotion MTX micro
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Select "MTB" or "Developer" (F3 or F4).
3. Enter the correct
password for the user (default setting in the basic project:
no password).
4. After having pressed "Enter" to confirm, the current "MTB" or "Develop‐
er" user is displayed.
Fig.5-5: Changing the user (to set the address)
Setting the IP address
The IP address of the MTX micro must be identical with the IP address in the
project. The following settings should be made:
IP Address → 192.168.142.250
Subnet Mask → 255.255.255.0
Gateway → 0.0.0.0
The gateway address is only required for operation in a network. If there is a
direct connection to the PC, address 0.0.0.0 is used.
1. Select the "System" operating area on the HMI control panel, then "Op‐
tion" (F8).
2. Select "SetIP" (F3), enter "192.168.142.250" in the input field, and press
Enter to confirm.
3. „Select "etMask" (F4), enter "255.255.255.0" in the input field, and press
Enter to confirm.
4. Select "GateWay" (F5), enter "0.0.0.0" in the input field, and press Enter
to confirm.
5.
DOK-MTXMIC-EASY*******-CO04-EN-P
Rexroth IndraMotion MTX micro Easy setup for Standard Turning and Milling Machines
Bosch Rexroth AG 53/141
Software Installation and Basic Projects

Table of Contents

Other manuals for Bosch Rexroth IndraMotion MTX micro

Related product manuals