Fig.6-15: MSD file names
A total of 2048 messages can be defined. Each message is assigned a serial
number from 1 to 2048. The list of messages can contain gaps.
The messages are distinguished as follows:
● Machine errors have an ID of E
● Machine warnings have an ID of W
● Machine notes have an ID of M
There is a message text for every message; optionally, a cause-and-remedy
text can also be defined. The length of each message text is limited to 128
characters.
Fig.6-16: mzatexte file structure
● Texts
which
cannot
be displayed in the ASCII character set
can be entered in UTF8 character coding. When using the
UTF8 format, the text length is shorter for up to 2/3 of the dis‐
playable characters corresponding to the coding effort.
● UTF-8 files are saved to the notepad. Select UTF-8 as coding
in the "Save As..." dialog. The characters will then be saved in
UTF-8 format. Caution: The NC editor can only edit ASCII files.
These files must be edited externally via the notepad and then
be copied to the system.
DOK-MTXMIC-EASY*******-CO04-EN-P
Rexroth IndraMotion MTX micro Easy setup for Standard Turning and Milling Machines
Bosch Rexroth AG 73/141
PLC Startup